Property grades such as 8, 10 and 12 are familiar on metric nuts, just as property classes such as 8.8, 10.9 and 12.9 are familiar on bolts. On a made-to-print order the nut grade, any proof-load or hardness requirement, and compatibility with the mating bolt are taken from the current revision. A “normal grade 8 nut” or a grade that is usually paired with a class 8.8 bolt is not a substitute for the call-out that the print actually shows, and a bolt class is not used to invent a nut grade that the nut drawing does not state.
SUNHY reviews nut grades on special nuts and installation elements and on weld nuts, against the customer drawing. The notes on property classes on made-to-print fasteners and on internal threads, tapping and gauging belong beside this one. This article looks at how a nut grade should be written in an RFQ, and at what is not assumed when the print is silent.
The grade on the revision is the requirement
A complete call-out names the nut grade or the standard designation, the thread, and any proof load, hardness, or other mechanical requirement that the print or the referenced standard imposes. If the print names a grade but is silent on proof load, the requirements of the named standard, when that standard is clearly invoked, are reviewed; a local shorthand without a standard is an open item. If the print is silent on grade, a familiar 8, 10 or 12 is not assumed. Head or face marks, when they are required, are produced as specified.
Special nuts — prevailing-torque nuts, weld nuts, clinch nuts, T-nuts and other installation nuts — still have a mechanical requirement when the print or the standard states one. The installation feature does not replace the grade, and the grade does not replace the installation geometry. Those families are already discussed in the notes on prevailing-torque lock nuts, on weld nuts and special nuts and on clinch nuts and rivet nuts.
Mating bolts are information, not a rewrite
Compatibility with a mating bolt class is a design decision on the customer side. Two drawings can be reviewed as a pair if both are sent; the bolt drawing is not used to invent a nut grade, a proof load, or a thread class on the nut, or the reverse. “To suit our 10.9 bolt” is not a grade. If a customer standard that pairs nut grades with bolt classes is already chosen, it should be named on the revision or attached to the RFQ.
Thread class of fit and nut grade are different characteristics. A tight or a coated thread does not change the grade, and a high grade does not loosen or tighten the gauging requirement. Both have to be visible when they are required, including after coating if that condition is specified, as in the note on internal-thread gauging. Friction and lubrication, when they are specified, stay with the finish and with any torque-tension requirement, as in the note on friction class and torque-tension.
Material, heat treatment and process
The grade, together with the nut style and the size, influences the starting material and the heat-treatment condition. Those choices are reviewed, as in the notes on carbon and alloy steels and on heat treatment. They do not authorise a change of grade to make forming easier, and they do not authorise a heat treatment that the print does not require. Stainless nuts, when they are specified, follow the stainless grade and condition on the print, as in the note on stainless fasteners, not a carbon-steel grade 8 practice.
The method used to form the nut and to produce the internal thread is a process decision and is stated rather than assumed. A change of grade, of heat treatment, or of threading method after samples have been approved is a process change and is re-validated before serial release — see the notes on cold-heading tooling and on prototype samples and series production.
Inspection, proof load and certificates
Proof load, hardness, thread gauging, and any prevailing-torque or installation check are used when the print or the order requires that evidence, not automatically in every possible form. If a particular proof-load test, a hardness location, or a first-article layout is already decided, name it. A bolt that “tightens up” is not a substitute for a proof-load or a grade mark that is written on the print. Certificates and any EN 10204 3.1, PPAP or IMDS evidence are confirmed per order when required, as already described in the notes on hardness and tensile checks, on material certificates and on order documents.
First-article or layout inspection, when required, should be planned on the production-intent route, including the heat-treatment and coating state in which the nut will be tested. Measuring a soft, uncoated, fully machined sample and treating the result as approval of a formed, heat-treated and coated series nut is a category error. That rule is the same as in the note on first-article inspection.
What to write in the RFQ
Quote the nut grade or designation, any proof-load or hardness requirement, the thread and its gauging condition (including after coating if required), the material, the finish, the volume and the documents you need, all as they appear on the current revision. If a mating-bolt drawing or a pairing standard exists, attach or name it for information. Send the print with the request form.
Send the print. The scope is confirmed before quote.
Email the current drawing revision, or use the request form. Unspecified points will be flagged before production rather than assumed.
This article is a capability and commercial note. It is not a certificate, a dimensional data book, or evidence of customer approval. Catalogue type codes and example grades do not replace the customer’s item number, material specification or drawing revision.