Hardness, proof load and tensile checks on a made-to-print fastener are inspection activities. They are added to the plan when the print, the referenced standard or the order requires them. They are not performed automatically on every lot, and a photograph of a test bench on this site is not evidence that a particular test will be run. The method, the location of readings, the number of pieces and the way the results are reported all have to be agreed.
SUNHY includes this kind of mechanical evidence on bolts, screws and studs and on other fasteners when it is specified. The quality page already states that hardness, proof load and tensile properties are added when the order requires them. This note explains how to write that requirement so that it can be confirmed, rather than assumed.
What the requirement has to name
A complete request names the property or the test, the governing standard or the limits on the print, and whether the check is for first article, for a stated frequency, or for every lot. “Hardness to be checked” is a starting point, not a method. If core and surface hardness are both specified, or if a case-depth measurement is required after carburizing, those distinctions belong in the same instruction. The note on heat treatment explains why they cannot be inferred from the process name alone.
Proof load, wedge tensile, or another mechanical test is likewise taken from the standard or the order. The acceptance values follow the property class or the limits on the drawing — classes such as 8.8, 10.9 and 12.9, or nut grades 8, 10 and 12, when those are specified. A class written on the print does not, by itself, create a test plan; the test still has to be requested or invoked.
Location, condition and the parts that are tested
Hardness readings have a location. Under-head, end of the point, a prepared section, or another stated position can give different information. If the specification already fixes the location, it should be followed; if it does not, the proposed location should be agreed rather than invented at the machine. Coatings are usually removed or avoided at the reading, as the method requires.
Tests are performed on parts in the condition the requirement describes — typically after heat treatment, and before or after coating as the standard or the order says. A tensile result from a soft machined prototype is not evidence for a heat-treated series part. That is the same process-condition rule as in the notes on prototype samples and on first-article inspection.
Records, certificates and what they are not
When a test is agreed, the record is linked to the lot that was tested. It is not reused from a neighbouring lot or from a previous revision without a written basis. A material certificate such as EN 10204 3.1 may include or refer to mechanical values for the starting material; that is not automatically the same as a finished-part hardness or tensile test. Both kinds of document are confirmed per order — see documents that can be confirmed per order and matching the material grade to the certificate.
Results are not published here as generic site data, and they are not a PPM claim. A capability index on hardness, if it is required at all, is a separate request and follows the rules in the note on process capability.
High-strength parts and coatings
On parts at 10.9 or 12.9, and on other high-strength items, mechanical testing often sits alongside a coating and hydrogen-embrittlement requirement. The tests described in this note do not replace that control, and a baking or relief step does not replace a hardness check. The existing article on coatings for high-strength fasteners remains the place for those coating questions.
Stainless parts in 304 (A2), 316 (A4) or 410, when they are specified, follow the condition and the tests on their own print. A carbon-steel hardness table is not applied to them by analogy.
Sample size, destructive tests and remaining pieces
Mechanical tests are often destructive. The number of pieces to be tested, and whether they are extra parts or taken from the delivery quantity, should be agreed. A tensile test that consumes a bolt is not an unstated deduction from a tight delivery count. If a particular sample size is already fixed in the customer standard, it should be named; if it is not, a proposed number can be written into the quotation rather than decided at the last moment.
Remaining pieces from a test, broken samples, and the retention of a reference part follow the same record rules as other inspection evidence. They are kept when the order or the programme so requires, for an agreed period, not for a generic published number of years. If a witness test or a customer laboratory is to be used, that arrangement is part of the confirmation, and the lot identity of the pieces that travel must still match the records that stay with the rest of the shipment.
What to write in the RFQ
State the hardness, proof-load or tensile checks you need, the standard or the limits, the frequency, and the condition of the parts, together with the property class, the material and the current drawing revision. Send the drawing with the request form or to anna@sunhyings.com. A wider list of enquiry items is in what to include in a made-to-print RFQ.
This article is a capability and commercial note. It is not a certificate, a dimensional data book, or evidence of customer approval. Catalogue type codes and example grades do not replace the customer’s item number, material specification or drawing revision.