A lock nut on a made-to-print programme is defined by the drawing, not by a catalogue term such as “prevailing torque” or “nyloc”. The type of locking feature, the nut grade, the thread and the finish all have to be read from the current revision. A standard commercial lock nut is not substituted for a missing type, and a type used on a sister part is not assumed.
SUNHY reviews prevailing-torque and lock nuts as part of the special nuts and installation elements family, against the customer drawing. All-metal prevailing-torque forms and nuts with a polymer or nylon insert can be produced when they are specified. The examples on this site illustrate capability; they are not a stock list.
Name the type, not only the function
The print should say how the prevailing torque is produced: an all-metal deformed-thread or beam feature, a polymer or nylon insert, or another specified arrangement. “A lock nut” or “self-locking” is not a complete call-out. If the customer standard that defines the type, the torque range or the reuse condition is already chosen, it should be named on the revision or in the RFQ.
Insert nuts and all-metal nuts are not interchangeable. A polymer insert has temperature and media limits that come from the customer specification, not from a general remark on this site. If the application sits near a heat source, in a fluid, or in a process that would degrade an insert, the type has to reflect that — and it has to be written on the print, not inferred at quotation.
Grade, thread and the mating part
Nut grades such as 8, 10 and 12, where they are specified, are taken from the print in the same way as on a plain nut. Compatibility with the mating bolt or stud class is a design decision on the customer side. The thread system, pitch and class of fit are also taken from the drawing; they are not completed from a catalogue default. Those thread points are covered more fully in the note on thread standards, pitch and gauging.
Useful thread, the location of the locking feature, and any reduced-height or flange geometry belong on the same revision. A flange lock nut is not substituted for a plain hex lock nut, or the reverse, to make heading or coating more convenient.
Coating, temperature and the locking feature
Coating thickness and the method of coating can affect both the thread class and a polymer insert. If the finished, coated thread must gauge, or if a prevailing-torque test is required after coating, that condition has to be written into the enquiry and into the inspection plan. Over-tapping or an informal change to the insert is not a shop-floor adjustment; it is a process decision that must follow the print.
Friction class and torque-tension behaviour, when they are specified for the joint, should be named with the coating. They are discussed in the note on friction class and torque-tension. On high-strength mating parts, any hydrogen-embrittlement control belongs in the same pack of requirements — see coatings for high-strength fasteners.
Inspection of the locking feature
Prevailing-torque or removal-torque checks are included when the drawing or the order requires them, not automatically on every lot. If a first-article layout, a specified gauge, or a reuse test is already decided, name it. A visual check that “the insert is present” is not a substitute for a torque requirement that is written on the print.
Documents such as EN 10204 3.1, inspection records or an IMDS entry are confirmed per order, as described in the note on documents that can be confirmed per order.
First-on torque, reuse and the governing standard
When a prevailing-torque range is specified, the enquiry should name the standard or the customer method that defines first-on torque, prevailing torque during tightening, and any reuse or five-time removal test. Those figures are not taken from a generic table on this site, and they are not copied from a different nut on the same programme unless the print says they apply. If only a type is named and no torque range is given, that is an open item if torque is to be a documented characteristic.
The mating bolt or stud, the lubrication condition and the presence of a patch or a coating all affect the result. If the test is to be done on a specified bolt, in a coated or lubricated state, that condition belongs in the plan. A dry test with an unspecified screw is not a substitute for a method the customer standard already describes. Results, when they are required, are recorded for the lot that was tested and are not reused from a neighbouring item.
What to write in the RFQ
Name the locking type as it appears on the current revision, together with the nut grade, the thread, the finish, any temperature or media limit that the specification already states, and the tests or documents you need. Send the drawing with the request form or to anna@sunhyings.com. Related installation elements are described in the notes on clinch nuts and rivet nuts and on T-nuts and other special installation nuts. A wider RFQ list is in what to include in a made-to-print RFQ.
This article is a capability and commercial note. It is not a certificate, a dimensional data book, or evidence of customer approval. Catalogue type codes and example grades do not replace the customer’s item number, material specification or drawing revision.